EPA 609 study guide
EPA 609, administered by U.S, is mapped here as 6 topic areas; the heaviest are MVAC Refrigerants — The Three Cans (22%), Recovery, Recycle & Recharge + SAE Standards (20%) and Section 609 Regulations (18%).
About this course: 609 for cars, 608 for buildings. Nail R-12 vs R-134a vs R-1234yf, the recovery procedures, and the 84% open-book cut.
EPA 609 at a glance
- Questions
- 50
- Time allowed
- provider-set
- Passing standard
- EPA Section 609 MVAC Technician Certification
- Format
- Open-book multiple-choice
- Standard / edition
- current §609 rule (2026)
- Administered by
- U.S
Source: current §609 rule (2026), U.S. Confirm current details with the exam owner before you book.
Topic areas and weights
| Topic area | Weight | Concepts | Guide |
|---|---|---|---|
| Clean Air Act & §609 Basics | 13% | 7 | Section below |
| MVAC Refrigerants — The Three Cans | 22% | 10 | Section below |
| Oils, Mixing & Contamination | 15% | 7 | Section below |
| Recovery, Recycle & Recharge + SAE Standards | 20% | 9 | Section below |
| Section 609 Regulations | 18% | 8 | Section below |
| Refrigerant Safety & Handling | 12% | 6 | Section below |
Study plan in this course
- Clean Air Act & Section 609 — Cars vs. Buildings — 7 cards · free
- MVAC Refrigerants — R-12, R-134a & R-1234yf — 10 cards · free
- Oils, Cross-Charging & Contamination — 7 cards · full course
- Recovery, Recycle, Recharge & SAE Equipment Standards — 9 cards · full course
- Section 609 Regulations — Venting, Sales & Records — 8 cards · full course
- Refrigerant Safety, PPE & Cylinder Handling — 6 cards · full course
Clean Air Act & §609 Basics
Clean Air Act & §609 Basics carries 13% of the EPA 609 blueprint used in this course, the 5th-largest of its 6 weighted areas. It spans 7 concepts. The course teaches it in 1 study unit: Clean Air Act & Section 609 — Cars vs. Buildings.
What Clean Air Act & §609 Basics covers
- What does EPA Section 609 cover, and how is it different from Section 608? — Clean Air Act §609 + 40 CFR Part 82 Subpart B + SAE J-standards + EPA-approved provider study materials
- Do you need Section 609 certification, and does it expire? — Clean Air Act §609 + 40 CFR Part 82 Subpart B + SAE J-standards + EPA-approved provider study materials
- What does the ozone layer have to do with refrigerants? — Clean Air Act §609 + 40 CFR Part 82 Subpart B + SAE J-standards + EPA-approved provider study materials
- If R-134a doesn't hurt the ozone layer, why is it being phased down? — Clean Air Act §609 + 40 CFR Part 82 Subpart B + SAE J-standards + EPA-approved provider study materials
- Is it ever legal to knowingly vent MVAC refrigerant into the air? — Clean Air Act §609 + 40 CFR Part 82 Subpart B + SAE J-standards + EPA-approved provider study materials
- Why does the refrigerant landscape keep changing? — Clean Air Act §609 + 40 CFR Part 82 Subpart B + SAE J-standards + EPA-approved provider study materials
- Who issues the rules and who administers the §609 exam? — Clean Air Act §609 + 40 CFR Part 82 Subpart B + SAE J-standards + EPA-approved provider study materials
Official references for Clean Air Act & §609 Basics
- Clean Air Act §609 + 40 CFR Part 82 Subpart B + SAE J-standards + EPA-approved provider study materials
In the app this area comes with 7 memory cards and 7 module-quiz questions and is part of the free starting modules.
MVAC Refrigerants — The Three Cans
MVAC Refrigerants — The Three Cans carries 22% of the EPA 609 blueprint used in this course, the largest of its 6 weighted areas. It spans 10 concepts. The course teaches it in 1 study unit: MVAC Refrigerants — R-12, R-134a & R-1234yf.
What MVAC Refrigerants — The Three Cans covers
- What is R-12, and why was it phased out? — Clean Air Act §609 + 40 CFR Part 82 Subpart B + SAE J-standards + EPA-approved provider study materials
- What is R-134a, and what is its environmental drawback? — Clean Air Act §609 + 40 CFR Part 82 Subpart B + SAE J-standards + EPA-approved provider study materials
- What is R-1234yf, and why did automakers switch to it? — Clean Air Act §609 + 40 CFR Part 82 Subpart B + SAE J-standards + EPA-approved provider study materials
- What does the safety class 'A2L' mean for R-1234yf? — Clean Air Act §609 + 40 CFR Part 82 Subpart B + SAE J-standards + EPA-approved provider study materials
- Why do R-12, R-134a, and R-1234yf systems use different service fittings? — Clean Air Act §609 + 40 CFR Part 82 Subpart B + SAE J-standards + EPA-approved provider study materials
- What is R-744, and where might you see it? — Clean Air Act §609 + 40 CFR Part 82 Subpart B + SAE J-standards + EPA-approved provider study materials
- How can you tell what refrigerant is actually in a vehicle before you service it? — Clean Air Act §609 + 40 CFR Part 82 Subpart B + SAE J-standards + EPA-approved provider study materials
- Why are illegal hydrocarbon 'drop-in' refrigerants dangerous in an MVAC system? — Clean Air Act §609 + 40 CFR Part 82 Subpart B + SAE J-standards + EPA-approved provider study materials
- Can you 'top off' a low A/C system by just adding refrigerant? — Clean Air Act §609 + 40 CFR Part 82 Subpart B + SAE J-standards + EPA-approved provider study materials
- Which refrigerant has zero ODP AND the lowest GWP of the three main MVAC refrigerants? — Clean Air Act §609 + 40 CFR Part 82 Subpart B + SAE J-standards + EPA-approved provider study materials
Official references for MVAC Refrigerants — The Three Cans
- Clean Air Act §609 + 40 CFR Part 82 Subpart B + SAE J-standards + EPA-approved provider study materials
In the app this area comes with 10 memory cards and 11 module-quiz questions and is part of the free starting modules.
Oils, Mixing & Contamination
Oils, Mixing & Contamination carries 15% of the EPA 609 blueprint used in this course, the 4th-largest of its 6 weighted areas. It spans 7 concepts. The course teaches it in 1 study unit: Oils, Cross-Charging & Contamination.
What Oils, Mixing & Contamination covers
- Which lubricating oil goes with each MVAC refrigerant? — Clean Air Act §609 + 40 CFR Part 82 Subpart B + SAE J-standards + EPA-approved provider study materials
- What happens if you mix two different refrigerants in one system or cylinder? — Clean Air Act §609 + 40 CFR Part 82 Subpart B + SAE J-standards + EPA-approved provider study materials
- What is 'cross-charging,' and why is it a problem? — Clean Air Act §609 + 40 CFR Part 82 Subpart B + SAE J-standards + EPA-approved provider study materials
- How do you know if the refrigerant in a system is contaminated? — Clean Air Act §609 + 40 CFR Part 82 Subpart B + SAE J-standards + EPA-approved provider study materials
- What do you do with refrigerant the identifier flags as contaminated? — Clean Air Act §609 + 40 CFR Part 82 Subpart B + SAE J-standards + EPA-approved provider study materials
- Can one recovery machine safely service both R-134a and R-1234yf? — Clean Air Act §609 + 40 CFR Part 82 Subpart B + SAE J-standards + EPA-approved provider study materials
- If you retrofit an old R-12 system to R-134a, what must you do? — Clean Air Act §609 + 40 CFR Part 82 Subpart B + SAE J-standards + EPA-approved provider study materials
Official references for Oils, Mixing & Contamination
- Clean Air Act §609 + 40 CFR Part 82 Subpart B + SAE J-standards + EPA-approved provider study materials
In the app this area comes with 7 memory cards and 8 module-quiz questions in the full course.
Recovery, Recycle & Recharge + SAE Standards
Recovery, Recycle & Recharge + SAE Standards carries 20% of the EPA 609 blueprint used in this course, the second-largest of its 6 weighted areas. It spans 9 concepts. The course teaches it in 1 study unit: Recovery, Recycle, Recharge & SAE Equipment Standards.
What Recovery, Recycle & Recharge + SAE Standards covers
- What is the first thing you must do before opening an MVAC system for repair? — Clean Air Act §609 + 40 CFR Part 82 Subpart B + SAE J-standards + EPA-approved provider study materials
- What's the difference between 'recover,' 'recycle,' and 'recharge'? — Clean Air Act §609 + 40 CFR Part 82 Subpart B + SAE J-standards + EPA-approved provider study materials
- Which SAE standard covers R-134a recovery/recycle equipment? — Clean Air Act §609 + 40 CFR Part 82 Subpart B + SAE J-standards + EPA-approved provider study materials
- Which SAE standard covers R-1234yf service equipment? — Clean Air Act §609 + 40 CFR Part 82 Subpart B + SAE J-standards + EPA-approved provider study materials
- What does SAE J2810 cover, and what is SAE J3030? — Clean Air Act §609 + 40 CFR Part 82 Subpart B + SAE J-standards + EPA-approved provider study materials
- After recovery and repair, why do you evacuate the system? — Clean Air Act §609 + 40 CFR Part 82 Subpart B + SAE J-standards + EPA-approved provider study materials
- How much refrigerant do you put back into the system? — Clean Air Act §609 + 40 CFR Part 82 Subpart B + SAE J-standards + EPA-approved provider study materials
- How should you find a refrigerant leak — and what should you NOT use? — Clean Air Act §609 + 40 CFR Part 82 Subpart B + SAE J-standards + EPA-approved provider study materials
- Why must recovery equipment be matched to the refrigerant type? — Clean Air Act §609 + 40 CFR Part 82 Subpart B + SAE J-standards + EPA-approved provider study materials
Official references for Recovery, Recycle & Recharge + SAE Standards
- Clean Air Act §609 + 40 CFR Part 82 Subpart B + SAE J-standards + EPA-approved provider study materials
In the app this area comes with 9 memory cards and 10 module-quiz questions in the full course.
Section 609 Regulations
Section 609 Regulations carries 18% of the EPA 609 blueprint used in this course, the third-largest of its 6 weighted areas. It spans 8 concepts. The course teaches it in 1 study unit: Section 609 Regulations — Venting, Sales & Records.
What Section 609 Regulations covers
- What does the Section 609 venting prohibition actually say? — Clean Air Act §609 + 40 CFR Part 82 Subpart B + SAE J-standards + EPA-approved provider study materials
- Who is allowed to BUY MVAC refrigerant? — Clean Air Act §609 + 40 CFR Part 82 Subpart B + SAE J-standards + EPA-approved provider study materials
- Why must small DIY cans of R-134a have a self-sealing valve? — Clean Air Act §609 + 40 CFR Part 82 Subpart B + SAE J-standards + EPA-approved provider study materials
- Do shops have to keep records, and of what? — Clean Air Act §609 + 40 CFR Part 82 Subpart B + SAE J-standards + EPA-approved provider study materials
- What equipment is a shop required to use for MVAC service? — Clean Air Act §609 + 40 CFR Part 82 Subpart B + SAE J-standards + EPA-approved provider study materials
- Does the 609 venting ban still apply to a vehicle being scrapped or to the leftover in a small can? — Clean Air Act §609 + 40 CFR Part 82 Subpart B + SAE J-standards + EPA-approved provider study materials
- Can a non-certified person legally service a car's A/C for pay if a certified tech 'supervises'? — Clean Air Act §609 + 40 CFR Part 82 Subpart B + SAE J-standards + EPA-approved provider study materials
- What are the penalties for violating Section 609 / the venting prohibition? — Clean Air Act §609 + 40 CFR Part 82 Subpart B + SAE J-standards + EPA-approved provider study materials
Official references for Section 609 Regulations
- Clean Air Act §609 + 40 CFR Part 82 Subpart B + SAE J-standards + EPA-approved provider study materials
In the app this area comes with 8 memory cards and 9 module-quiz questions in the full course.
Refrigerant Safety & Handling
Refrigerant Safety & Handling carries 12% of the EPA 609 blueprint used in this course, the 6th-largest of its 6 weighted areas. It spans 6 concepts. The course teaches it in 1 study unit: Refrigerant Safety, PPE & Cylinder Handling.
What Refrigerant Safety & Handling covers
- What injury can liquid refrigerant cause on contact, and how do you protect against it? — Clean Air Act §609 + 40 CFR Part 82 Subpart B + SAE J-standards + EPA-approved provider study materials
- Why is working with refrigerant in a confined or unventilated space dangerous? — Clean Air Act §609 + 40 CFR Part 82 Subpart B + SAE J-standards + EPA-approved provider study materials
- What extra precaution does R-1234yf's A2L flammability require? — Clean Air Act §609 + 40 CFR Part 82 Subpart B + SAE J-standards + EPA-approved provider study materials
- How full should a recovery/refrigerant cylinder be filled, and why? — Clean Air Act §609 + 40 CFR Part 82 Subpart B + SAE J-standards + EPA-approved provider study materials
- How should refrigerant cylinders be stored and handled? — Clean Air Act §609 + 40 CFR Part 82 Subpart B + SAE J-standards + EPA-approved provider study materials
- Which refrigerant runs at extreme pressure, and what does that mean for handling? — Clean Air Act §609 + 40 CFR Part 82 Subpart B + SAE J-standards + EPA-approved provider study materials
Official references for Refrigerant Safety & Handling
- Clean Air Act §609 + 40 CFR Part 82 Subpart B + SAE J-standards + EPA-approved provider study materials
In the app this area comes with 6 memory cards and 6 module-quiz questions in the full course.
Official references
- Clean Air Act §609 + 40 CFR Part 82 Subpart B + SAE J-standards + EPA-approved provider study materials
- Clean Air Act: §609
- 40 CFR Part 82, Subpart B
- EPA-approved provider study materials
- AIM Act of 2020 + 40 CFR Part 84 + Montreal Protocol context
- SAE International J-standards: J2788, J2843, J2810: J3030